Gas Chromatograph BK-GC112A
Features:
1. 7-inch LCD display indicates temperature, gas flow and heating curve.
2. Self-test function and automatic fault recognition function.
3. 8 pcs external extension interfaces can connect with control valve.
4. Equipped with a flame ionization detector(FID).
5. Multi-core and 32-bit embedded hardware system ensures the reliable operation.
6. Synchronous external trigger function and the external signal(auto sampler, thermal analyzer, etc.) can start the equipment and workstation software at the same time.
7. With chromatography workstation software to process data.
8. Memory function: can store 20 samples test modes.
9. One key start up function.
Technical Parameters:
Model
BK-GC112A Oven
Capacity
22L
Temp. Range
RT+5°C~400°C
Temp. Accuracy
±0.1 °C
Temp. Program
9 steps
Program Total Time
9999.9min
Max Temp. Heating Rate
60°C/min
Sample Injector
Temp. Range
RT+7°C~420°C
Column or split injector can be installed
Carrier gas flow control type: Constant pressure mode
Max. Quantity
3pcs
Pre Column Pressure Range
0~400kpa
Pre Column Pressure Accuracy
0.1kpa
Flow Setting Range
H2: 0~200ml/min
N2: 0~150ml/min
Detector
Temp. Range
RT+7°C~420°C
Hydrogen Flame Ionization Detector(FID)
Logarithmic amplifier
High voltage switch control
Baseline signal display
Detection Limit: ≤3*10-12g/s(Sample: n-hexadecane)
Baseline Noise: ≤5*10-14A
Baseline Draft: ≤6*10-13A
Dynamic Range: 107
RSD: ≤3%
Thermal Conductivity Detector(TCD)(Optional)
Sensitivity: 8000mv.ml/mg(Sample: n-hexadecane)
Baseline Noise: ≤0.05mV
Baseline Draft: ≤0.15mV/30min
Dynamic Range: 105
Power Supply
AC220V±10%, 50Hz
Standard Accessory
FID detector, Capillary injection system, Chromatography workstation software, RS232 port, LAN port
Optional Accessory
TCD detector, Chromatographic column, Gas purifier
Package Size(W*D*H)
735*725*835mm
Gross Weight
80kg
Technical Parameters:
Model
Oven
Capacity
22L
Temp. Range
RT+5°C~400°C
Temp. Accuracy
±0.1 °C
Temp. Program
9 steps
Program Total Time
9999.9min
Max Temp. Heating Rate
60°C/min
Sample Injector
Temp. Range
RT+7°C~420°C
Column or split injector can be installed
Carrier gas flow control type: Constant pressure mode
Max. Quantity
3pcs
Pre Column Pressure Range
0~400kpa
Pre Column Pressure Accuracy
0.1kpa
Flow Setting Range
H2: 0~200ml/min
N2: 0~150ml/min
Detector
Temp. Range
RT+7°C~420°C
Hydrogen Flame Ionization Detector(FID)
Logarithmic amplifier
High voltage switch control
Baseline signal display
Detection Limit: ≤3*10-12g/s(Sample: n-hexadecane)
Baseline Noise: ≤5*10-14A
Baseline Draft: ≤6*10-13A
Dynamic Range: 107
RSD: ≤3%
Thermal Conductivity Detector(TCD)(Optional)
Sensitivity: 8000mv.ml/mg(Sample: n-hexadecane)
Baseline Noise: ≤0.05mV
Baseline Draft: ≤0.15mV/30min
Dynamic Range: 105
Power Supply
AC220V±10%, 50Hz
Standard Accessory
FID detector, Capillary injection system, Chromatography workstation software, RS232 port, LAN port
Optional Accessory
TCD detector, Chromatographic column, Gas purifier
Package Size(W*D*H)
735*725*835mm
Gross Weight
80kg
Gas Chromatograph BK-GC112A — professional solution in the Gas Chromatograph category
Gas Chromatograph BK-GC112A is a modern business-class equipment designed for daily operation in demanding conditions. The combination of reliability, accuracy and durability makes this product the optimal choice for companies seeking consistent process quality, predictable results and reduced operating costs. The purchase price is a reasonable investment in the development and scaling of the enterprise.
Why Gas Chromatograph BK-GC112A
- Reliability and durability: industrial-grade design and materials withstand intense loads.
- Accuracy and repeatability: stable performance that reduces the risk of defects and downtime.
- Process efficiency: optimizing staff time and increasing productivity at every stage.
- Compliance with standards: manufactured taking into account current international requirements for the business segment.
- Ease of integration: Gas Chromatograph BK-GC112A fits easily into existing process lines and IT infrastructure.
Areas of application Gas Chromatograph
Gas Chromatograph solutions are widely used in manufacturing, research laboratories, construction sites, energy and agricultural sectors, pharmaceutical and food industries. Implementing Gas Chromatograph BK-GC112A allows you to increase productivity, ensure accuracy of operations and optimize resource utilization across the entire enterprise.
Key benefits for business
Return on investment
Reduced service costs and downtime, predictive budget planning, fast ROI thanks to stable operation.
Scalability
Readiness to expand capacity and integrate with other solutions without re-engineering processes.
Safety and quality control
Compliance with standards, which simplifies audits and increases the trust of customers and partners.
Technical highlights
- Industrial reliability of components and assemblies for long-term trouble-free operation.
- Stable parameters that ensure repeatability of results and product quality.
- Energy efficiency and optimized life cycle cost of ownership.
- Compatibility with related equipment and standard data exchange protocols.
Service and support
Together with Gas Chromatograph BK-GC112A you receive professional advice on selection, commissioning and personnel training. We provide warranty and post-warranty service, prompt delivery of consumables and spare parts. Our team supports projects from the procurement stage to the stable operation of the complex so that your business receives the expected result every day.
To select a package for your needs or to receive a commercial offer, add Gas Chromatograph BK-GC112A to the cart or contact our manager. We will help integrate Gas Chromatograph into existing processes without downtime and unnecessary costs.
No questions about this product, be the first and ask your question.