Two-component high-precision isothermal calorimeter I-Cal 2000 HPC
Two-component high-precision isothermal calorimeter with interchangeable reference cells. Maximum sample size: 125 ml per channel. Meets ASTM C1702, C1679, C563, C1897, EN 196-11 and RILEM R3 standards.. Includes computer-controlled Peltier cooling/heating chamber. Can be used with paste, mortar or real concrete samples. Includes all accessories (cables, reusable sample containers, laptop computer with pre-installed software). 12 months warranty against any manufacturing defects.
Included:
I-Cal recorder. Software for working with the device
I-Cal Reports. Software for reporting and data analysis
The I-Cal 2000 HPC (High Precision Calorimeter) is a 2-channel isothermal calorimeter. Like all Calmetrix I-Cal isothermal calorimeter models, the I-Cal 2000 HPC has a sample size of up to 125 ml, which can be used for applications in many industries, including research and concrete property studies, as well as daily quality control needs in cement and concrete production. Interchangeable reference cells make the I-Cal 2000 HPC a versatile instrument that allows you to test cement, mortar and real concrete or other materials of different types and sizes of samples.
The I-Cal 2000 HPC is suitable for long-term cement hydration testing up to 28 days or longer.
In addition, I-Cal 2000 HPC fully complies with ASTM C1679, ASTM C1702, ASTM C563 and EN 196-11.
As with other Calmetrix I-Cal calorimeters, the ambient temperature around the samples is controlled by a computer via the Calmetrix software interface, using precise sensors that measure the heat flow generated by the cement hydration reaction. But the I-Cal 2000 HPC stands out with its intelligent design that minimizes sensitivity to external conditions. This means more consistent results, as well as reliable performance even in unconditioned environments, a clear advantage in terms of reproducibility and cost savings for field laboratories or non-conditioned facilities. In addition, the two active sample cells of the I-Cal 2000 HPC do not contact each other, thus keeping crosstalk below 0.1%.
Application:
The I-Cal 2000 HPC is well suited for applications in research and development of cement and concrete properties, as well as for daily quality control needs in cement and concrete production. Typical uses:
• measurement of heat of hydration according to ASTM C1702
• identification of potential material incompatibility (between cement and admixtures, etc.)
• sulfate optimization
• tests for sensitivity to changes in impurity content or other material
• evaluation of compressive strength using heat of hydration curves
• determining the activation energy for predicting thermal cracking
• tests for sensitivity to temperature fluctuations
• mixture design optimization and statistical analysis of efficiency
• test temperatures above 50 °C (up to 70 °C), e.g. for studies of delayed ettringite formation
• characteristics of additional cement materials
When to consider I-Cal 2000 HPC:
I-Cal 2000 HPC — correct isothermal calorimeter for experiments , which has such characteristics :
- curing at any temperature, if necessary up to 70 °C
- testing duration of any duration, up to 28 days or even more
- Heat of hydration test according to ASTM C1702
- high-precision research with the need for the best signal-to-noise ratio (minimum crosstalk)
Two-component high-precision isothermal calorimeter I-Cal 2000 HPC — professional solution in the Калориметры category
Two-component high-precision isothermal calorimeter I-Cal 2000 HPC is a modern business-class equipment designed for daily operation in demanding conditions. The combination of reliability, accuracy and durability makes this product the optimal choice for companies seeking consistent process quality, predictable results and reduced operating costs. The purchase price is a reasonable investment in the development and scaling of the enterprise.
Why Two-component high-precision isothermal calorimeter I-Cal 2000 HPC
- Reliability and durability: industrial-grade design and materials withstand intense loads.
- Accuracy and repeatability: stable performance that reduces the risk of defects and downtime.
- Process efficiency: optimizing staff time and increasing productivity at every stage.
- Compliance with standards: manufactured taking into account current international requirements for the business segment.
- Ease of integration: Two-component high-precision isothermal calorimeter I-Cal 2000 HPC fits easily into existing process lines and IT infrastructure.
Areas of application Калориметры
Калориметры solutions are widely used in manufacturing, research laboratories, construction sites, energy and agricultural sectors, pharmaceutical and food industries. Implementing Two-component high-precision isothermal calorimeter I-Cal 2000 HPC allows you to increase productivity, ensure accuracy of operations and optimize resource utilization across the entire enterprise.
Key benefits for business
Return on investment
Reduced service costs and downtime, predictive budget planning, fast ROI thanks to stable operation.
Scalability
Readiness to expand capacity and integrate with other solutions without re-engineering processes.
Safety and quality control
Compliance with standards, which simplifies audits and increases the trust of customers and partners.
Technical highlights
- Industrial reliability of components and assemblies for long-term trouble-free operation.
- Stable parameters that ensure repeatability of results and product quality.
- Energy efficiency and optimized life cycle cost of ownership.
- Compatibility with related equipment and standard data exchange protocols.
Service and support
Together with Two-component high-precision isothermal calorimeter I-Cal 2000 HPC you receive professional advice on selection, commissioning and personnel training. We provide warranty and post-warranty service, prompt delivery of consumables and spare parts. Our team supports projects from the procurement stage to the stable operation of the complex so that your business receives the expected result every day.
To select a package for your needs or to receive a commercial offer, add Two-component high-precision isothermal calorimeter I-Cal 2000 HPC to the cart or contact our manager. We will help integrate Калориметры into existing processes without downtime and unnecessary costs.
No questions about this product, be the first and ask your question.