Table Top Low Speed Centrifuge BKC-TL5VI BKC-TL61II BKC-TL6lV
Features:
1. Microcomputer control, large screen color LCD, full touch screen operation interface.
2. Brushless AC variable frequency motor drive.
3. Double door cover lock system, ensure running safety.
4. Provide 20 kinds of working program storage, easy to use and improve work efficiency.
5. Provide 15 kinds of acceleration/deceleration.
6. It has two timing functions: setting and jog.
7. Differential centrifugation: five differential centrifugation procedures are reserved.
8. Double layer steel structure, spray anti-corrosion coating surface of centrifugal chamber.
9. Automatic balance and unbalance protection.
10. Soft braking function, it can effectively prevent sample resuspension and protect sensitive samples.
11. Countdown function: the countdown in seconds, real-time display of remaining working time.
12. The centrifuge can customize 485 communication interface function and operate through remote control.
13. Sunken exhaust passage, it can prevent aerosol pollution during centrifugation.
Technical Parameters:
Model
BKC-TL5VI
BKC-TL6III
BKC-TL6IV
Max. Capacity
4*750ml
8*100ml
4*500ml
Max. Speed
6000rpm
Max. RCF
5502×g
Speed Precision
±10rpm
Timing Range
1s~99h59min59s/jog
Noise
≤62dB
≤60dB
≤60dB
Power Supply
AC220V, 50/60Hz(Standard); AC110V, 50/60Hz(Optional): External transformer
External Size(W*D*H)mm
640*515*450
540*425*400
610*485*400
Package Size(W'D*H)mm
750*645*630
620*555*550
750*645*630
Gross Weight(kg)
86
48
62
Rotor for BKC-TL5VI:
Rotor No.
Max. Capacity
Max. Speed(rpm)
Max. RCF(×g)
No.1 Swing Rotor
4*750ml
4200
3727
Adapter
4*500ml
4200
3727
Adapter
4*250ml(corning tube)
Adapter
4*250ml
Adapter
12*100ml
Adapter
20*50ml(▲)
Adapter
56*10/15ml(▲)
Adapter
76*10ml vacuum blood tube
Adapter
96*3/5/7ml vacuum blood tube
Adapter
148*5ml(RIA tube)
Adapter
28*50ml(●)
No.2 Uncapped Swing Rotor
96*3/5ml vacuum blood tube
4200
3727
Uncapped Adapter
96*3/5ml vacuum blood tube
No.3 Anti-pollution Swing Rotor
4*750ml
4200
3727
No.4 Swing Rotor
16*100ml
16*50ml
64*10/15ml
4200
3727
No.5 Swing Rotor
148*5ml vacuum blood tube
4200
3451
No.6 Angle Rotor
6*50ml
6000
5502
No.7 Microplate Rotor【DWP/MTP】
2*96-well/2*2*96-well
5000
3530
No.8 Microplate Rotor【DWP/MTP】
4*96-well/2*4*96-well
4000
3667
Rotor for BKC-TL6III:
Rotor No.
Max. Capacity
Max. Speed(rpm)
Max. RCF(×g)
No.1 Swing Rotor
4*100ml
5000
4500
Adapter
4*100ml
5000
4500
Adapter
4*50ml
Adapter
12*15ml(▲)
Adapter
16*5/10ml
No.2 Swing Rotor
4*100ml
4500
3645
Adapter
4*100ml
4500
3645
Adapter
8*50ml
Adapter
24*10/15ml(▲/urine sediment tube)
No.3 Swing Rotor
8*100ml
4200
3175
Adapter
8*100ml
4200
3175
Adapter
8*50ml
Adapter
32*10/15ml
No.6 Swing Rotor
40*5/7ml vacuum blood tube
4500
3645
Adapter 1
40*5/7ml vacuum blood tube
4500
3645
Adapter 2
24*10/15ml(▲/urine sediment tube)
No.4 Swing Rotor
32*5ml
4500
3645
Adapter 1
32*5/7ml vacuum blood tube
4500
3645
No.5 Uncapped Swing Rotor
32*5ml vacuum blood tube
4500
3645
Uncapped Adapter
32*5ml vacuum blood tube
4500
3645
No.7 Swing Rotor
48*5/7ml vacuum blood tube
4500
3645
Adapter
48*5/7ml vacuum blood tube
No.8 Uncapped Swing Rotor
48*5ml vacuum blood tube
4500
3645
Uncapped Adapter
48*5ml vacuum blood tube
No.9 Angle Rotor
12*5/10ml
6000
5502
No.10 Angle Rotor
6*50ml
6000
5502
No.11 Microplate Rotor【DWP/MTP】
2*96-well /2*2*96-well
5000
3530
Rotor for BKC-TL6IV:
Rotor No.
Max. Capacity
Max. Speed(rpm)
Max. RCF(×g)
No.1 Swing Rotor
4*300ml(round cup)
4500
3894
Adapter
4*250ml
4500
3894
Adapter
4*100ml
Adapter
12*50ml
Adapter
40*10ml vacuum blood tube
Adapter
28*15ml(▲)
Adapter
56*3/5ml vacuum blood tube
Adapter
76*5ml(RIA tube)
No.2 Swing Rotor
4*500ml(round cup)
4200
3451
Adapter
4*250ml
4200
3451
Adapter
8*100ml
Adapter
16*50ml
Adapter
56*10ml(●)
Adapter
40*15ml(▲)
Adapter
68*3/ 5/7ml vacuum blood tube
Adapter
96*5ml(RIA tube)
No.3 Uncapped Swing Rotor
68*3/5ml vacuum blood tube
Uncapped Adapter
68*3/5ml vacuum blood tube
No.4 Angle Rotor
6*50ml
6000
5502
No.5 Angle Rotor
12*5/10ml
6000
No.6 Microplate Rotor【DWP/MTP】
2*96-well/2*2*96-well
5000
3530
Note: The default is round-bottom tube, with mark (▲) is sharp-bottom tube.
Model
BKC-TL5VI
BKC-TL6III
BKC-TL6IV
Max. Capacity
4*750ml
8*100ml
4*500ml
Max. Speed
6000rpm
Max. RCF
5502×g
Speed Precision
±10rpm
Timing Range
1s~99h59min59s/jog
Noise
≤62dB
≤60dB
≤60dB
Power Supply
AC220V, 50/60Hz(Standard); AC110V, 50/60Hz(Optional): External transformer
External Size(W*D*H)mm
640*515*450
540*425*400
610*485*400
Package Size(W'D*H)mm
750*645*630
620*555*550
750*645*630
Gross Weight(kg)
86
48
62
Rotor No.
Max. Capacity
Max. Speed(rpm)
Max. RCF(×g)
No.1 Swing Rotor
4*750ml
4200
3727
Adapter
4*500ml
4200
3727
Adapter
4*250ml(corning tube)
Adapter
4*250ml
Adapter
12*100ml
Adapter
20*50ml(▲)
Adapter
56*10/15ml(▲)
Adapter
76*10ml vacuum blood tube
Adapter
96*3/5/7ml vacuum blood tube
Adapter
148*5ml(RIA tube)
Adapter
28*50ml(●)
No.2 Uncapped Swing Rotor
96*3/5ml vacuum blood tube
4200
3727
Uncapped Adapter
96*3/5ml vacuum blood tube
No.3 Anti-pollution Swing Rotor
4*750ml
4200
3727
No.4 Swing Rotor
16*100ml
16*50ml
64*10/15ml
4200
3727
No.5 Swing Rotor
148*5ml vacuum blood tube
4200
3451
No.6 Angle Rotor
6*50ml
6000
5502
No.7 Microplate Rotor【DWP/MTP】
2*96-well/2*2*96-well
5000
3530
No.8 Microplate Rotor【DWP/MTP】
4*96-well/2*4*96-well
4000
3667
Rotor No.
Max. Capacity
Max. Speed(rpm)
Max. RCF(×g)
No.1 Swing Rotor
4*100ml
5000
4500
Adapter
4*100ml
5000
4500
Adapter
4*50ml
Adapter
12*15ml(▲)
Adapter
16*5/10ml
No.2 Swing Rotor
4*100ml
4500
3645
Adapter
4*100ml
4500
3645
Adapter
8*50ml
Adapter
24*10/15ml(▲/urine sediment tube)
No.3 Swing Rotor
8*100ml
4200
3175
Adapter
8*100ml
4200
3175
Adapter
8*50ml
Adapter
32*10/15ml
No.6 Swing Rotor
40*5/7ml vacuum blood tube
4500
3645
Adapter 1
40*5/7ml vacuum blood tube
4500
3645
Adapter 2
24*10/15ml(▲/urine sediment tube)
No.4 Swing Rotor
32*5ml
4500
3645
Adapter 1
32*5/7ml vacuum blood tube
4500
3645
No.5 Uncapped Swing Rotor
32*5ml vacuum blood tube
4500
3645
Uncapped Adapter
32*5ml vacuum blood tube
4500
3645
No.7 Swing Rotor
48*5/7ml vacuum blood tube
4500
3645
Adapter
48*5/7ml vacuum blood tube
No.8 Uncapped Swing Rotor
48*5ml vacuum blood tube
4500
3645
Uncapped Adapter
48*5ml vacuum blood tube
No.9 Angle Rotor
12*5/10ml
6000
5502
No.10 Angle Rotor
6*50ml
6000
5502
No.11 Microplate Rotor【DWP/MTP】
2*96-well /2*2*96-well
5000
3530
Rotor No.
Max. Capacity
Max. Speed(rpm)
Max. RCF(×g)
No.1 Swing Rotor
4*300ml(round cup)
4500
3894
Adapter
4*250ml
4500
3894
Adapter
4*100ml
Adapter
12*50ml
Adapter
40*10ml vacuum blood tube
Adapter
28*15ml(▲)
Adapter
56*3/5ml vacuum blood tube
Adapter
76*5ml(RIA tube)
No.2 Swing Rotor
4*500ml(round cup)
4200
3451
Adapter
4*250ml
4200
3451
Adapter
8*100ml
Adapter
16*50ml
Adapter
56*10ml(●)
Adapter
40*15ml(▲)
Adapter
68*3/ 5/7ml vacuum blood tube
Adapter
96*5ml(RIA tube)
No.3 Uncapped Swing Rotor
68*3/5ml vacuum blood tube
Uncapped Adapter
68*3/5ml vacuum blood tube
No.4 Angle Rotor
6*50ml
6000
5502
No.5 Angle Rotor
12*5/10ml
6000
No.6 Microplate Rotor【DWP/MTP】
2*96-well/2*2*96-well
5000
3530
Table Top Low Speed Centrifuge BKC-TL5VI BKC-TL61II BKC-TL6lV — professional solution in the Low Speed Centrifuge category
Table Top Low Speed Centrifuge BKC-TL5VI BKC-TL61II BKC-TL6lV is a modern business-class equipment designed for daily operation in demanding conditions. The combination of reliability, accuracy and durability makes this product the optimal choice for companies seeking consistent process quality, predictable results and reduced operating costs. The purchase price is a reasonable investment in the development and scaling of the enterprise.
Why Table Top Low Speed Centrifuge BKC-TL5VI BKC-TL61II BKC-TL6lV
- Reliability and durability: industrial-grade design and materials withstand intense loads.
- Accuracy and repeatability: stable performance that reduces the risk of defects and downtime.
- Process efficiency: optimizing staff time and increasing productivity at every stage.
- Compliance with standards: manufactured taking into account current international requirements for the business segment.
- Ease of integration: Table Top Low Speed Centrifuge BKC-TL5VI BKC-TL61II BKC-TL6lV fits easily into existing process lines and IT infrastructure.
Areas of application Low Speed Centrifuge
Low Speed Centrifuge solutions are widely used in manufacturing, research laboratories, construction sites, energy and agricultural sectors, pharmaceutical and food industries. Implementing Table Top Low Speed Centrifuge BKC-TL5VI BKC-TL61II BKC-TL6lV allows you to increase productivity, ensure accuracy of operations and optimize resource utilization across the entire enterprise.
Key benefits for business
Return on investment
Reduced service costs and downtime, predictive budget planning, fast ROI thanks to stable operation.
Scalability
Readiness to expand capacity and integrate with other solutions without re-engineering processes.
Safety and quality control
Compliance with standards, which simplifies audits and increases the trust of customers and partners.
Technical highlights
- Industrial reliability of components and assemblies for long-term trouble-free operation.
- Stable parameters that ensure repeatability of results and product quality.
- Energy efficiency and optimized life cycle cost of ownership.
- Compatibility with related equipment and standard data exchange protocols.
Service and support
Together with Table Top Low Speed Centrifuge BKC-TL5VI BKC-TL61II BKC-TL6lV you receive professional advice on selection, commissioning and personnel training. We provide warranty and post-warranty service, prompt delivery of consumables and spare parts. Our team supports projects from the procurement stage to the stable operation of the complex so that your business receives the expected result every day.
To select a package for your needs or to receive a commercial offer, add Table Top Low Speed Centrifuge BKC-TL5VI BKC-TL61II BKC-TL6lV to the cart or contact our manager. We will help integrate Low Speed Centrifuge into existing processes without downtime and unnecessary costs.
No questions about this product, be the first and ask your question.