Catalog
Client
Language:
0675082385
Our location:
Legal address: Ukraine, 49023, Dnipro, Yaselna blvd. 1, office 332
Actual address: Ukraine, 49006, Dnipro, Stepana Bandera st., 25
Phones:
Working hours
  • Mon-Fri: 9am-6pm
  • Sat: 10am-5pm
  • Sun: 11am-4pm
E-mail
Go to contacts
0 0
Catalog
Home
Wishlist
0
Compare
0
Contacts

Portable Conductivity/TDS/Salinity Meter PH-520 PH-530 PH-531 PH-540

Brand: BIOBASE Group, Singapore Product Code: PH-520 PH-530 PH-531 PH-540 SKU: PH-520 PH-530 PH-531 PH-540
All about product
Description
Questions0
From a warehouse in Singapore
Portable Conductivity/TDS/Salinity Meter PH-520 PH-530 PH-531 PH-540
Portable Conductivity/TDS/Salinity Meter PH-520 PH-530 PH-531 PH-540
Portable Conductivity/TDS/Salinity Meter PH-520 PH-530 PH-531 PH-540
Portable Conductivity/TDS/Salinity Meter PH-520 PH-530 PH-531 PH-540
In Stock
Уточнюйте наявність у менеджера
Brand:BIOBASE
Delivery time:Within 7 days
Model:PH-520 PH-530 PH-531 PH-540
Product origin:CHINA
Supply capacity:Factory Direct Supply
Delivery
Payment
Portable Conductivity/TDS/Salinity Meter PH-520 PH-530 PH-531 PH-540
Description

PH-520 Features:

1. 1 to 3 points calibration with automatic recognition for conductivity standards.

2. Automatic electrode diagnosis shows the calibration points and factors.

3. Selectable cell constant, reference temperature, linear/non-linear and pure water compensation modes.

4. Automatic temperature compensation ensures accurate readings over the entire range.

5. Auto-Read function senses and locks the measurement endpoint.

6. Setup menu allows setting the number of calibration points, temperature unit, auto-power off, etc.

7. Reset function automatically resumes all settings back to the factory defaults.

8. Expanded memory stores or recalls up to 100 data sets.

9. USB communication interface for data transfer orconnecting a power adapter to meter.


PH-530/531/540 Features:

1. 1 to 5 points calibration with automatic recognition for conductivity standards.

2. Automatic electrode diagnosis shows the calibration points and factors.

3. Selectable cell constant, reference temperature, TDS factor, linear and pure water compensations, seawater and practical salinity measurement modes.

4. Automatic temperature compensation ensures accurate readings over the entire range.

5. Auto-Read function senses and locks the measurement endpoint.

6. Calibration due alarm prompts user to calibrate the meter regularly.

7. Auto-Power Off effectively conserves battery life.

8. Setup menu allows setting the number of calibration points, stabilitycriteria,temperature unit, date and time, etc.

9. Reset function automatically resumes all settings back to the factory defaults.

10. Expanded memory stores or recalls up to 500 data sets.

11. USB communication interface is easy to transfer data to PC.

12. Multi-mode powerscheme(batteries, power adapter and USB port) ensures that using the meter smoothly.

 

Accessories:

Meter, CON-1 conductivity electrode, temperature probe, standard solutions and carrying case.


Technical Parameters:

Model

PH-520

PH-530

PH-531

PH-540

Conductivity

Range

Standard

CON-1: 2μs/cm~20000μs/cm

Optional

CON-0.01: 0.01μs/cm~0.1μs/cm

CON-0.1: 0.1μs/cm~2μs/cm

CON-10: 20000μs/cm~200ms/cm

Accuracy

±0.5% F.S.

Resolution

0.001, 0.01, 0.1, 1

Calibration Points

1 to 3 points(PH-520), 1 to 5 points(PH- 530/531/540)

Calibration Solutions

10μS/cm, 84pS/cm, 1413pS/cm, 12.88mS/cm, 111.8mS/cm

TDS

Range

/

0~10.00, 100.0,

1000ppm, 10.00,

200.0ppt

/

0~10.00, 100.0,

1000ppm, 10.00,

200.0ppt

Accuracy

/

±1%F.S.

/

±1%F.S.

Resolution

/

0.01, 0.1, 1

/

0.01, 0.1, 1

TDS Factor

/

0.1~1.0(default 0.5)

/

0.1~1.0(default 0.5)

Salinity

Range

/

0.00~42.00psu, 0.00~80.00ppt

Accuracy

/

±1% F.S.

Resolution

/

0.01

Resistivity

Range

/

0.00~20.00MΩ

Accuracy

/

±1% F.S.

Resolution

/

0.01

Temperature

Range

0~105°C/32~221°F

Accuracy

±0.5°C/±0.9°F

Resolution

0.1°C/0.1°F

Offset Calibration

1 point, reading ±10°C

Other

Specifications

Temperature Compensation

0~100°C, manual or automatic

Temperature Coefficient

Linear(0.0~10.0%/°C), non-linear, pure water

Reference Temperature

20/25°C

Cell Constant

K=0.1, 1, 10

Stability Criteria

/

Low or high

Calibration Due Alarm

/

1 to 31 days or off

Hold Function

Manual or auto-endpoint

Auto-Off

30 minutes after last key pressed(PH-520), 10, 20 or 30 minutes after last key pressed(PH-530/531/540)

Memory

100 data sets(PH-520), 500 data sets(PH-530/531/540)

Communication Interface

USB

Connector

6-pin mini-DIN, 3.5mm jack socket

Display

Custom LCD(80*60mm)

Power Requirements

3*1.5V AA batteries or DC5V power adapter

Battery Life

Approximately 150 hours(Turn off the backlight)

Dimensions(mm)

170*85*30

Weight(kg)

300g

Package Size(W*D*H)mm

475*155*350

Gross Weight(kg)

2kg

 

 


Portable Conductivity/TDS/Salinity Meter PH-520 PH-530 PH-531 PH-540 — professional solution in the pH meters category

Portable Conductivity/TDS/Salinity Meter PH-520 PH-530 PH-531 PH-540 is a modern business-class equipment designed for daily operation in demanding conditions. The combination of reliability, accuracy and durability makes this product the optimal choice for companies seeking consistent process quality, predictable results and reduced operating costs. The purchase price is a reasonable investment in the development and scaling of the enterprise.

Why Portable Conductivity/TDS/Salinity Meter PH-520 PH-530 PH-531 PH-540

  • Reliability and durability: industrial-grade design and materials withstand intense loads.
  • Accuracy and repeatability: stable performance that reduces the risk of defects and downtime.
  • Process efficiency: optimizing staff time and increasing productivity at every stage.
  • Compliance with standards: manufactured taking into account current international requirements for the business segment.
  • Ease of integration: Portable Conductivity/TDS/Salinity Meter PH-520 PH-530 PH-531 PH-540 fits easily into existing process lines and IT infrastructure.

Areas of application pH meters

pH meters solutions are widely used in manufacturing, research laboratories, construction sites, energy and agricultural sectors, pharmaceutical and food industries. Implementing Portable Conductivity/TDS/Salinity Meter PH-520 PH-530 PH-531 PH-540 allows you to increase productivity, ensure accuracy of operations and optimize resource utilization across the entire enterprise.

Key benefits for business

Return on investment

Reduced service costs and downtime, predictive budget planning, fast ROI thanks to stable operation.

Scalability

Readiness to expand capacity and integrate with other solutions without re-engineering processes.

Safety and quality control

Compliance with standards, which simplifies audits and increases the trust of customers and partners.

Technical highlights

  • Industrial reliability of components and assemblies for long-term trouble-free operation.
  • Stable parameters that ensure repeatability of results and product quality.
  • Energy efficiency and optimized life cycle cost of ownership.
  • Compatibility with related equipment and standard data exchange protocols.

Service and support

Together with Portable Conductivity/TDS/Salinity Meter PH-520 PH-530 PH-531 PH-540 you receive professional advice on selection, commissioning and personnel training. We provide warranty and post-warranty service, prompt delivery of consumables and spare parts. Our team supports projects from the procurement stage to the stable operation of the complex so that your business receives the expected result every day.

To select a package for your needs or to receive a commercial offer, add Portable Conductivity/TDS/Salinity Meter PH-520 PH-530 PH-531 PH-540 to the cart or contact our manager. We will help integrate pH meters into existing processes without downtime and unnecessary costs.




Answers & questions
Add your question and we will answer as soon as possible.

No questions about this product, be the first and ask your question.