Infant Incubator BK-3201
Features:
1. LCD display.
2. Double control modes of bed temperature and skin temperature.
3. Double-layer thermostatic cover, automatic air curtain device.
4. Humidity control function.
5. Air&Oxygen blender.
6. Oxygen supply system.
7. Baby cot is infinitely adjustable.
8. 24 kinds of sound and light alarm, comprehensive protection of baby safety.
Technical Parameters:
General Parameters
Item
Specifications
Power Supply
AC220V, 50/60Hz(Standard) 1320VA;
AC110V, 60Hz(Optional)
Size(L*W*H)
950*645*(1250~1450)mm
Maximum Heater Output Power(220VAC)
Air Chamber Heater: 330W
Water Tank Heater: 155W
Auxiliary Network Power Output
AC220V/50Hz, both maximum permissible currents are 220V 1.5A
Heater Indication
0~100%, 10% increasing amount
Temperature Control Mode
Bed temperature mode; The skin temperature mode
Bed Temperature Control Temperature Range
25.0~37.0℃;
37.1~39.0℃(Span mode)
Skin Temperature Control Range
34.0~37.0℃; 37.1~38.0℃(Span mode)
Skin Temperature Sensor Display Range
5.0~65.0℃
Heating Time
≤50min
Temperature Variability
≤0.5℃
Temperature Uniformity(Mattress in horizontal position)
≤0.8℃
Temperature Uniformity(Mattress in tilted position)
≤1.0℃
Difference Between Average Incubator Temperature and Control Temperature
≤1.5℃
Skin Temperature Sensor Accuracy
±0.3℃
Humidity Control
The running time of the tank after it is filled with distilled water
Humidity below 70%RH, at least 24h
Water Tank Capacity
1500ml
Humidity Display Range
0%RH~99%RH
Humidity Control Range
CAH%RH~90%RH(1% per adjustment)
Humidity Control Accuracy
±10%
Oxygen Concentration Control
Oxygen Concentration Display Range
0%~99%
Oxygen Concentration Display Resolution
1%
Oxygen Concentration Control Accuracy
±5% oxygen volume concentration
Oxygen Concentration Setting Range
21%~60%(1% per adjustment)
Oxygen Sensor Service Life
The maximum use time is 10000h at 100% oxygen concentration
Transport Storage
Temperature
-20℃~+55℃
Atmospheric Pressure Range
500hPa~1060hPa
Relative Humidity
≤93%RH
Packing Size/Gross Weight
1150*800*1600mm
190kg
The Work Environment
Relative Humidity
30%RH~75%RH
The Environment Temperature
+20℃~+30℃
Pressure Range
700hPa~1060hPa
Service Altitude
≤2000m
Over Voltage Category
II
Pollution Levels
2
Ambient Air Velocity
≤0.3m/s
Other Indicators
Environmental Noise In Incubator Baby Compartment
No more than 55dB(A) at stable temperature
Carbon Dioxide Concentration In The Infant Compartment
A mixture of 4% carbon dioxide and air was fed into an 8mm diameter tube in the vertical direction from the mat to the top of the box at 750mL/min to a point 10cm above the mattress center and 10cm above the center. The concentration was less than 0.5% after stabilization
The velocity of air flow over a baby's mattress
≤0.35m/s
General
Alarm
Power failure alarm, fan alarm, sensor alarm, deviation alarm, over temperature alarm, water tank placement error alarm, water shortage alarm
The System Alarm
Mcu1 and Mcu2 communication error alarm, Mcu2 and Mcu3 communication error alarm, analog-to-digital conversion chip 2544 failure alarm, analog-to-digital conversion chip 2548 failure alarm, over temperature alarm, temperature heating system failure, humidity heating system failure
Configuration:
Model
Type I+
Type I
Type II
Type III
Type IV
Temp. Control
Bed/Skin Temperature
Bed/Skin Temperature
Bed/Skin Temperature
Bed/Skin Temperature
Bed/Skin Temperature
Display
LCD
LCD
LCD
LCD
LCD
Bed Temp. Control Range
25℃~39℃
25℃~39℃
25℃~39℃
25℃~39℃
25℃~39℃
Skin Temp. Control Range
34℃~38℃
34℃~38℃
34℃~38℃
34℃~38℃
/
Humidity Control Range
CAH%~99%RH
CAH%~99%RH
CAH%~99%RH
/
/
Oxygen Control Range
21%~99%
21%~99%
/
/
/
Cabinet
Yes
Yes
Yes
Yes
Yes
Height Adjustable Yes
/ / / /
General Parameters
Item
Specifications
Power Supply
AC220V, 50/60Hz(Standard) 1320VA;
AC110V, 60Hz(Optional)
Size(L*W*H)
950*645*(1250~1450)mm
Maximum Heater Output Power(220VAC)
Air Chamber Heater: 330W
Water Tank Heater: 155W
Auxiliary Network Power Output
AC220V/50Hz, both maximum permissible currents are 220V 1.5A
Heater Indication
0~100%, 10% increasing amount
Temperature Control Mode
Bed temperature mode; The skin temperature mode
Bed Temperature Control Temperature Range
25.0~37.0℃;
37.1~39.0℃(Span mode)
Skin Temperature Control Range
34.0~37.0℃; 37.1~38.0℃(Span mode)
Skin Temperature Sensor Display Range
5.0~65.0℃
Heating Time
≤50min
Temperature Variability
≤0.5℃
Temperature Uniformity(Mattress in horizontal position)
≤0.8℃
Temperature Uniformity(Mattress in tilted position)
≤1.0℃
Difference Between Average Incubator Temperature and Control Temperature
≤1.5℃
Skin Temperature Sensor Accuracy
±0.3℃
Humidity Control
The running time of the tank after it is filled with distilled water
Humidity below 70%RH, at least 24h
Water Tank Capacity
1500ml
Humidity Display Range
0%RH~99%RH
Humidity Control Range
CAH%RH~90%RH(1% per adjustment)
Humidity Control Accuracy
±10%
Oxygen Concentration Control
Oxygen Concentration Display Range
0%~99%
Oxygen Concentration Display Resolution
1%
Oxygen Concentration Control Accuracy
±5% oxygen volume concentration
Oxygen Concentration Setting Range
21%~60%(1% per adjustment)
Oxygen Sensor Service Life
The maximum use time is 10000h at 100% oxygen concentration
Transport Storage
Temperature
-20℃~+55℃
Atmospheric Pressure Range
500hPa~1060hPa
Relative Humidity
≤93%RH
Packing Size/Gross Weight
1150*800*1600mm
190kg
The Work Environment
Relative Humidity
30%RH~75%RH
The Environment Temperature
+20℃~+30℃
Pressure Range
700hPa~1060hPa
Service Altitude
≤2000m
Over Voltage Category
II
Pollution Levels
2
Ambient Air Velocity
≤0.3m/s
Other Indicators
Environmental Noise In Incubator Baby Compartment
No more than 55dB(A) at stable temperature
Carbon Dioxide Concentration In The Infant Compartment
A mixture of 4% carbon dioxide and air was fed into an 8mm diameter tube in the vertical direction from the mat to the top of the box at 750mL/min to a point 10cm above the mattress center and 10cm above the center. The concentration was less than 0.5% after stabilization
The velocity of air flow over a baby's mattress
≤0.35m/s
General
Alarm
Power failure alarm, fan alarm, sensor alarm, deviation alarm, over temperature alarm, water tank placement error alarm, water shortage alarm
The System Alarm
Mcu1 and Mcu2 communication error alarm, Mcu2 and Mcu3 communication error alarm, analog-to-digital conversion chip 2544 failure alarm, analog-to-digital conversion chip 2548 failure alarm, over temperature alarm, temperature heating system failure, humidity heating system failure
Model
Type I+
Type I
Type II
Type III
Type IV
Temp. Control
Bed/Skin Temperature
Bed/Skin Temperature
Bed/Skin Temperature
Bed/Skin Temperature
Bed/Skin Temperature
Display
LCD
LCD
LCD
LCD
LCD
Bed Temp. Control Range
25℃~39℃
25℃~39℃
25℃~39℃
25℃~39℃
25℃~39℃
Skin Temp. Control Range
34℃~38℃
34℃~38℃
34℃~38℃
34℃~38℃
/
Humidity Control Range
CAH%~99%RH
CAH%~99%RH
CAH%~99%RH
/
/
Oxygen Control Range
21%~99%
21%~99%
/
/
/
Cabinet
Yes
Yes
Yes
Yes
Yes
Infant Incubator BK-3201 — professional solution in the New Products category
Infant Incubator BK-3201 is a modern business-class equipment designed for daily operation in demanding conditions. The combination of reliability, accuracy and durability makes this product the optimal choice for companies seeking consistent process quality, predictable results and reduced operating costs. The purchase price is a reasonable investment in the development and scaling of the enterprise.
Why Infant Incubator BK-3201
- Reliability and durability: industrial-grade design and materials withstand intense loads.
- Accuracy and repeatability: stable performance that reduces the risk of defects and downtime.
- Process efficiency: optimizing staff time and increasing productivity at every stage.
- Compliance with standards: manufactured taking into account current international requirements for the business segment.
- Ease of integration: Infant Incubator BK-3201 fits easily into existing process lines and IT infrastructure.
Areas of application New Products
New Products solutions are widely used in manufacturing, research laboratories, construction sites, energy and agricultural sectors, pharmaceutical and food industries. Implementing Infant Incubator BK-3201 allows you to increase productivity, ensure accuracy of operations and optimize resource utilization across the entire enterprise.
Key benefits for business
Return on investment
Reduced service costs and downtime, predictive budget planning, fast ROI thanks to stable operation.
Scalability
Readiness to expand capacity and integrate with other solutions without re-engineering processes.
Safety and quality control
Compliance with standards, which simplifies audits and increases the trust of customers and partners.
Technical highlights
- Industrial reliability of components and assemblies for long-term trouble-free operation.
- Stable parameters that ensure repeatability of results and product quality.
- Energy efficiency and optimized life cycle cost of ownership.
- Compatibility with related equipment and standard data exchange protocols.
Service and support
Together with Infant Incubator BK-3201 you receive professional advice on selection, commissioning and personnel training. We provide warranty and post-warranty service, prompt delivery of consumables and spare parts. Our team supports projects from the procurement stage to the stable operation of the complex so that your business receives the expected result every day.
To select a package for your needs or to receive a commercial offer, add Infant Incubator BK-3201 to the cart or contact our manager. We will help integrate New Products into existing processes without downtime and unnecessary costs.
No questions about this product, be the first and ask your question.