Gas Chromatograph BK-GC900
Features:
1. Ethernet communication interface is adopted, so that the instrument can realize long -distance data transmission through the internal LAN of the enterprise, which is convenient for the management of analysis data.
2. The unique design of the injection port solves the injection discrimination, and the dual-column compensation function not only solves the baseline drift caused by temperature programming, but also reduces the influence of backgroundnoise, which can lead to lower detection limits.
3. Unique vaporization chamber design, smaller dead volume; replacement of accessories such as injection pad, liner, polarizer, collector, nozzle can be done with one hand; packed column, capillary injector, TCD, FID detector and other main bodies. The replacement only requires a wrench to be completely disassembled, and the maintenance is very convenient.
4. The intelligent rear door system has stepless variable inlet and outlet air volume, which shortens the stable balance time of the system after programmed heating/cooling.
5. The inlet can be installed up to 4 types(packed column, capillary column split/splitless injection system can be used), multiple detectors with the same or different detectors are installed, automatic/manual gas injection device can be selected, top Empty sampler, thermal desorption sampler, pyrolysis furnace sampler, methane reformer, etc.
6. The instrument is equipped with a 4.3-inch color LCD touch screen and keyboard input for user operation.
7. Adopt the dual-stable gas path design of primary pressure stabilizer valve and stabilizer valve/pressure stabilizer valve With seven temperature control devices, the temperature control accuracy is lower than ±0.1℃.
8. With double over-temperature protection and power-off protection function.
9. With linkage trigger signal acquisition system.
10. With fault self-check and alarm function.
Technical Parameters:
Model
BK-GC900
Oven
Temp. Range
RT+5~450℃
Temp. Accuracy
≤±0.1℃
Temp. Program
20-phase
Max. Temp. Heating Rate
40℃/min
Time Range
0~655min
Internal Size
250*270*170mm
Detector
Hydrogen Flame Ionization Detector(FID)
Detection Limit: ≤5×10-12g/s(100ng/μl n-hexadecane-isooctane solution)
Temperature 450℃
Compatible with packed and capillary columns
Baseline Drift: ≤2*10-13A/30min
Baseline Noise: 3*10-14A
Linear Range:≥107
Thermal Conductivity Detector(TCD)
Sensitivity: >5000mv.ml/mg(50mg/ml toluene-benzene solution)
Temperature 400℃
Baseline Drift: ≤0.1mV/30min
Baseline Noise: 0.03mV
Linear Range: ≥105(±10%)
Injection Method
Various injection methods are available:
(1) Packed column injection;
(2) Packed column gasification injection;
(3) Capillary split/splitless injection: back pressure valve control technology, linear split;
(4) Six-way valve gas injection;
(5) On-line injection: continuous injection for 24 hours without supervision
Power Supply
AC220V±10%, 50/60Hz
Standard Accessory
FID detector, Chromatography workstation software, Capillary sampler
Optional Accessory
Sample injection system, TCD detector, Chromatographic column, Nickel catalytic converter
External Size(L*W*H)
530*502*508mm
Net Weight
42kg
Package Size(W*D*H)
750*710*720mm
Gross Weight
60kg
Model
BK-GC900
Oven
Temp. Range
RT+5~450℃
Temp. Accuracy
≤±0.1℃
Temp. Program
20-phase
Max. Temp. Heating Rate
40℃/min
Time Range
0~655min
Internal Size
250*270*170mm
Detector
Hydrogen Flame Ionization Detector(FID)
Detection Limit: ≤5×10-12g/s(100ng/μl n-hexadecane-isooctane solution)
Temperature 450℃
Compatible with packed and capillary columns
Baseline Drift: ≤2*10-13A/30min
Baseline Noise: 3*10-14A
Linear Range:≥107
Thermal Conductivity Detector(TCD)
Sensitivity: >5000mv.ml/mg(50mg/ml toluene-benzene solution)
Temperature 400℃
Baseline Drift: ≤0.1mV/30min
Baseline Noise: 0.03mV
Linear Range: ≥105(±10%)
Injection Method
Various injection methods are available:
(1) Packed column injection;
(2) Packed column gasification injection;
(3) Capillary split/splitless injection: back pressure valve control technology, linear split;
(4) Six-way valve gas injection;
(5) On-line injection: continuous injection for 24 hours without supervision
Power Supply
AC220V±10%, 50/60Hz
Standard Accessory
FID detector, Chromatography workstation software, Capillary sampler
Optional Accessory
Sample injection system, TCD detector, Chromatographic column, Nickel catalytic converter
External Size(L*W*H)
530*502*508mm
Net Weight
42kg
Package Size(W*D*H)
750*710*720mm
Gross Weight
60kg
Gas Chromatograph BK-GC900 — professional solution in the Gas Chromatograph category
Gas Chromatograph BK-GC900 is a modern business-class equipment designed for daily operation in demanding conditions. The combination of reliability, accuracy and durability makes this product the optimal choice for companies seeking consistent process quality, predictable results and reduced operating costs. The purchase price is a reasonable investment in the development and scaling of the enterprise.
Why Gas Chromatograph BK-GC900
- Reliability and durability: industrial-grade design and materials withstand intense loads.
- Accuracy and repeatability: stable performance that reduces the risk of defects and downtime.
- Process efficiency: optimizing staff time and increasing productivity at every stage.
- Compliance with standards: manufactured taking into account current international requirements for the business segment.
- Ease of integration: Gas Chromatograph BK-GC900 fits easily into existing process lines and IT infrastructure.
Areas of application Gas Chromatograph
Gas Chromatograph solutions are widely used in manufacturing, research laboratories, construction sites, energy and agricultural sectors, pharmaceutical and food industries. Implementing Gas Chromatograph BK-GC900 allows you to increase productivity, ensure accuracy of operations and optimize resource utilization across the entire enterprise.
Key benefits for business
Return on investment
Reduced service costs and downtime, predictive budget planning, fast ROI thanks to stable operation.
Scalability
Readiness to expand capacity and integrate with other solutions without re-engineering processes.
Safety and quality control
Compliance with standards, which simplifies audits and increases the trust of customers and partners.
Technical highlights
- Industrial reliability of components and assemblies for long-term trouble-free operation.
- Stable parameters that ensure repeatability of results and product quality.
- Energy efficiency and optimized life cycle cost of ownership.
- Compatibility with related equipment and standard data exchange protocols.
Service and support
Together with Gas Chromatograph BK-GC900 you receive professional advice on selection, commissioning and personnel training. We provide warranty and post-warranty service, prompt delivery of consumables and spare parts. Our team supports projects from the procurement stage to the stable operation of the complex so that your business receives the expected result every day.
To select a package for your needs or to receive a commercial offer, add Gas Chromatograph BK-GC900 to the cart or contact our manager. We will help integrate Gas Chromatograph into existing processes without downtime and unnecessary costs.
No questions about this product, be the first and ask your question.