You watched
Catalog
Client
Language:
0675082385
Our location:
Legal address: Ukraine, 49023, Dnipro, Yaselna blvd. 1, office 332
Actual address: Ukraine, 49006, Dnipro, Stepana Bandera st., 25
Phones:
Working hours
  • Mon-Fri: 9am-6pm
  • Sat: 10am-5pm
  • Sun: 11am-4pm
E-mail
Go to contacts
0 0
Catalog
Home
Viewed
2
Wishlist
0
Compare
0
Contacts

Automatic Nucleic Acid Extraction System BK-AutoHS96

Brand: BIOBASE Group, Singapore Product Code: 1333548865
All about product
Description
Questions0
From a warehouse in Singapore
Automatic Nucleic Acid Extraction System BK-AutoHS96
Automatic Nucleic Acid Extraction System BK-AutoHS96
Automatic Nucleic Acid Extraction System BK-AutoHS96
Automatic Nucleic Acid Extraction System BK-AutoHS96
Automatic Nucleic Acid Extraction System BK-AutoHS96
Automatic Nucleic Acid Extraction System BK-AutoHS96
Automatic Nucleic Acid Extraction System BK-AutoHS96
Automatic Nucleic Acid Extraction System BK-AutoHS96
Automatic Nucleic Acid Extraction System BK-AutoHS96
Automatic Nucleic Acid Extraction System BK-AutoHS96
In Stock
Уточнюйте наявність у менеджера
Brand:BIOBASE
Delivery time:Within 7 days
Product origin:CHINA
Supply capacity:Factory Direct Supply
Delivery
Payment
Automatic Nucleic Acid Extraction System BK-AutoHS96
Description

Features:

1. Accurate pipetting, air pressure correction can adapt to extreme environments such as flat ground, plateau, island, etc., to ensure the accuracy of pipetting

2. 96 samples can be processed within 60 minutes, realizing high-throughput processing of samples, saving time and effort

3. Reagent position and PCR plate position, can be refrigerated at 4℃

4. With high-efficiency filter, ultraviolet disinfection and sterilization, and safety door functions, effectively prevent microbial pollution

5. Multi-threaded control and three-module extraction can run three different extraction programs at the same time

6. Intelligent temperature control, over-temperature protection function

7. Preset multiple experimental programs, strong compatibility, suitable for various types of sample graphic guides, visualized operations

8. Nucleic acid products can be allocated to the 2*96 PCR reaction system to flexibly construct a variety of different PCR detection systems

nucleic acid Systemucleic acid extraction equipment


Technical Parameters:

Model

BK-AutoHS96

Extraction Method

Magnetic bead method

Working Mode

Automatic sampling + Nucleic acid extraction + PCR reaction system addition

Throughput

1~96, linear slide type sample rack

Extraction Volume

20~1000μl

Processing Time

Complete the processing of 96 samples within 60 minutes(Related to reagents)

Magnetic Bead Recovery

≥98%

Temp Range

RT~105℃, lysis and elution position

Temp Accuracy

0.1℃

Heating Method

Dry bath heating

Heating Speed

RT~100℃≤6min

Shaking Function

Up and down oscillation(1~5 gears adjustable)

Extraction Position

6(96-well deep well plate)

Robotic Arm

A robotic arm for adding samples and reagents

Pipetting Channel

2 channels

Liquid Detection

Pneumatic liquid level detection principle, intelligent detection of blocked needle

Pipetting Tip

50μl, 200μl,1000μl, disposable black conductive needle with filter element

Tip Amount

2~3 tips/sample

Pipetting Accuracy

10μl, CV≤3.0%, Accuracy≤5.0%, 50μl tip

50μl, CV≤2.0%, Accuracy≤2.0%, 1000μl tip

100μl, CV≤1.5%, Accuracy≤2.0%, 1000μl tip

Sample Volume

2~1000μl

Working Zone

2 pcr positions with cooling function

6 tip positions for three types of tips

2 reagent positions(5ml freezing tube rack position with cooling function, one reserved position)

Protective Function

Start up self-test, Power-off protection, High temperature alarm, Over-temperature protection, Tip removal protection

Disinfection Method

UV lamp(30W*1, 8W*1)

Illumination Lamp

10W LED lamp

Audible Alarm

Yes(Red and blue blinking)

Safety Door Design

With safety lock function, the safety door is opened and the program is suspended

Display

10.1 inch touch screen, Windows system

Scanning

Optional

Interface

LAN interface(Bi-direction LIS optional)

Contamination Control

Built-in air duct and HEPA filter can effectively filter internal aerosols and prevent cross-contamination

IAP Function

Firmware can be upgraded online at any time

Power Supply

110/220V, 50/60Hz

External Size(W*D*H)mm

1420*850*1842

Package Size(W*D*H)mm

Main Instrument: 1535*970*1180

Base: 1540*970*1160

Gross Weight(kg)

Main Instrument: 360

Base: 190


Automatic Nucleic Acid Extraction System BK-AutoHS96 — professional solution in the Nucleic Acid Extractor category

Automatic Nucleic Acid Extraction System BK-AutoHS96 is a modern business-class equipment designed for daily operation in demanding conditions. The combination of reliability, accuracy and durability makes this product the optimal choice for companies seeking consistent process quality, predictable results and reduced operating costs. The purchase price is a reasonable investment in the development and scaling of the enterprise.

Why Automatic Nucleic Acid Extraction System BK-AutoHS96

  • Reliability and durability: industrial-grade design and materials withstand intense loads.
  • Accuracy and repeatability: stable performance that reduces the risk of defects and downtime.
  • Process efficiency: optimizing staff time and increasing productivity at every stage.
  • Compliance with standards: manufactured taking into account current international requirements for the business segment.
  • Ease of integration: Automatic Nucleic Acid Extraction System BK-AutoHS96 fits easily into existing process lines and IT infrastructure.

Areas of application Nucleic Acid Extractor

Nucleic Acid Extractor solutions are widely used in manufacturing, research laboratories, construction sites, energy and agricultural sectors, pharmaceutical and food industries. Implementing Automatic Nucleic Acid Extraction System BK-AutoHS96 allows you to increase productivity, ensure accuracy of operations and optimize resource utilization across the entire enterprise.

Key benefits for business

Return on investment

Reduced service costs and downtime, predictive budget planning, fast ROI thanks to stable operation.

Scalability

Readiness to expand capacity and integrate with other solutions without re-engineering processes.

Safety and quality control

Compliance with standards, which simplifies audits and increases the trust of customers and partners.

Technical highlights

  • Industrial reliability of components and assemblies for long-term trouble-free operation.
  • Stable parameters that ensure repeatability of results and product quality.
  • Energy efficiency and optimized life cycle cost of ownership.
  • Compatibility with related equipment and standard data exchange protocols.

Service and support

Together with Automatic Nucleic Acid Extraction System BK-AutoHS96 you receive professional advice on selection, commissioning and personnel training. We provide warranty and post-warranty service, prompt delivery of consumables and spare parts. Our team supports projects from the procurement stage to the stable operation of the complex so that your business receives the expected result every day.

To select a package for your needs or to receive a commercial offer, add Automatic Nucleic Acid Extraction System BK-AutoHS96 to the cart or contact our manager. We will help integrate Nucleic Acid Extractor into existing processes without downtime and unnecessary costs.




Answers & questions
Add your question and we will answer as soon as possible.

No questions about this product, be the first and ask your question.

You watched
From a warehouse in Singapore
From a warehouse in Singapore