Atomic Absorption Spectrophotometer BK-AA4530F
Features:
1. Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer(optional).
2. Integrated floated optical platform design improves the optical system shock resistance stable.
3. Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.
4. Position adjusting: the flame burner can be set on the best position automatically.
5. Fully automated wavelength scanning and peak searching.
6. Complete safety chains protection equipment: warning and automatic safety protection for the wrong burner connection, leakage of the gas, under voltage of air and the abnormal flameout.
7. Deuterium lamp and self-absorption background calibration.
8. Measuring method: flame absorption method and emission method.
9. Result printing: parameter, data result and diagram.
10. Data processing: more than 500 data self-storage and cut-off storage, the analyzed result is stored in EXCEL format.
Technical Parameters:
Model
BK-AA4530F
Wavelength Range
190~900nm
Spectral Bandwidth
0.1, 0.2, 0.4, 1.0 and 2.0nm
Wavelength Accuracy
≤±0.15nm
Wavelength Repeatability
≤0.04nm
Base Line Stability
≤0.002A/30min(Cu)
Characteristic Concentration
0.02μg/ml/1%(Cu)
Detection Limit
0.004μg/ml(Cu)
Preciseness
≤0.5%
Grating
1800 lines/mm
Inflamer
All-metal titanium burner
Atomizer
Effective glass atomizer
Lamp Stand
8
D2 background Calibration
When the background is 1 A, the background ability should be deducted not less than 50 times; Self absorption background deduction method
Power Supply
220V, 50Hz
Packing Size(W*D*H)mm
860*705*755(Main instrument); 545*445*1385(Accessories)
Gross Weight(kg)
105(Main instrument); 100(Accessories)
Standard Accessories
Software; Inkjet printer; Oil free air compressor;
Acetylene reducing valve; Cu hollow cathode lamp; Air filter
Optional Accessories
Graphite furnace 4510GF; Hollow cathode lamp(Ag, Au, Ca, Cd, Cr, Fe, Hg, K, Au, Mg, Mn, Na, Ni, Pb, Zn, Sb, etc), Graphite tubes, Recirculating cooling water system, Hydride generator, Autosampler
Flame System:
Acetylene Air Burner
100mm
Ignition Dynamic Baseline Drift
≤0.006A/30min
Characteristic Concentration
≤0.025μg/ml/1%(Cu)
Related Standard Deviation of the Accuracy
≤0.5%(Cu, absorbance>0.8A) (Detection limit Cu≤0.008μg/ml)
Safety System
Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner
Graphite Furnace(Optional):
Max. Temperature
3000°C
Max Heating Speed
≥2000°C/S
Characteristic Quantity
Cd≤0.5*10-12g
Cu≤0.5*10-11g
Accuracy
Cu≤3%
Cd≤3%
Safety System
Over current protection, Low air pressure alarm/protection, Low cooling water flow alarm/protection
Power Supply
220V, 50Hz
Consumption
7000W
Packing Size(W*D*H)mm
740*640*700
Gross Weight(kg)
90
Model
BK-AA4530F
Wavelength Range
190~900nm
Spectral Bandwidth
0.1, 0.2, 0.4, 1.0 and 2.0nm
Wavelength Accuracy
≤±0.15nm
Wavelength Repeatability
≤0.04nm
Base Line Stability
≤0.002A/30min(Cu)
Characteristic Concentration
0.02μg/ml/1%(Cu)
Detection Limit
0.004μg/ml(Cu)
Preciseness
≤0.5%
Grating
1800 lines/mm
Inflamer
All-metal titanium burner
Atomizer
Effective glass atomizer
Lamp Stand
8
D2 background Calibration
When the background is 1 A, the background ability should be deducted not less than 50 times; Self absorption background deduction method
Power Supply
220V, 50Hz
Packing Size(W*D*H)mm
860*705*755(Main instrument); 545*445*1385(Accessories)
Gross Weight(kg)
105(Main instrument); 100(Accessories)
Standard Accessories
Software; Inkjet printer; Oil free air compressor;
Acetylene reducing valve; Cu hollow cathode lamp; Air filter
Optional Accessories
Graphite furnace 4510GF; Hollow cathode lamp(Ag, Au, Ca, Cd, Cr, Fe, Hg, K, Au, Mg, Mn, Na, Ni, Pb, Zn, Sb, etc), Graphite tubes, Recirculating cooling water system, Hydride generator, Autosampler
Acetylene Air Burner
100mm
Ignition Dynamic Baseline Drift
≤0.006A/30min
Characteristic Concentration
≤0.025μg/ml/1%(Cu)
Related Standard Deviation of the Accuracy
≤0.5%(Cu, absorbance>0.8A) (Detection limit Cu≤0.008μg/ml)
Safety System
Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner
Max. Temperature
3000°C
Max Heating Speed
≥2000°C/S
Characteristic Quantity
Cd≤0.5*10-12g
Cu≤0.5*10-11g
Accuracy
Cu≤3%
Cd≤3%
Safety System
Over current protection, Low air pressure alarm/protection, Low cooling water flow alarm/protection
Power Supply
220V, 50Hz
Consumption
7000W
Packing Size(W*D*H)mm
740*640*700
Gross Weight(kg)
90
Atomic Absorption Spectrophotometer BK-AA4530F — professional solution in the Spectrophotometers category
Atomic Absorption Spectrophotometer BK-AA4530F is a modern business-class equipment designed for daily operation in demanding conditions. The combination of reliability, accuracy and durability makes this product the optimal choice for companies seeking consistent process quality, predictable results and reduced operating costs. The purchase price is a reasonable investment in the development and scaling of the enterprise.
Why Atomic Absorption Spectrophotometer BK-AA4530F
- Reliability and durability: industrial-grade design and materials withstand intense loads.
- Accuracy and repeatability: stable performance that reduces the risk of defects and downtime.
- Process efficiency: optimizing staff time and increasing productivity at every stage.
- Compliance with standards: manufactured taking into account current international requirements for the business segment.
- Ease of integration: Atomic Absorption Spectrophotometer BK-AA4530F fits easily into existing process lines and IT infrastructure.
Areas of application Spectrophotometers
Spectrophotometers solutions are widely used in manufacturing, research laboratories, construction sites, energy and agricultural sectors, pharmaceutical and food industries. Implementing Atomic Absorption Spectrophotometer BK-AA4530F allows you to increase productivity, ensure accuracy of operations and optimize resource utilization across the entire enterprise.
Key benefits for business
Return on investment
Reduced service costs and downtime, predictive budget planning, fast ROI thanks to stable operation.
Scalability
Readiness to expand capacity and integrate with other solutions without re-engineering processes.
Safety and quality control
Compliance with standards, which simplifies audits and increases the trust of customers and partners.
Technical highlights
- Industrial reliability of components and assemblies for long-term trouble-free operation.
- Stable parameters that ensure repeatability of results and product quality.
- Energy efficiency and optimized life cycle cost of ownership.
- Compatibility with related equipment and standard data exchange protocols.
Service and support
Together with Atomic Absorption Spectrophotometer BK-AA4530F you receive professional advice on selection, commissioning and personnel training. We provide warranty and post-warranty service, prompt delivery of consumables and spare parts. Our team supports projects from the procurement stage to the stable operation of the complex so that your business receives the expected result every day.
To select a package for your needs or to receive a commercial offer, add Atomic Absorption Spectrophotometer BK-AA4530F to the cart or contact our manager. We will help integrate Spectrophotometers into existing processes without downtime and unnecessary costs.
No questions about this product, be the first and ask your question.