Atomic Absorption Spectrophotometer BK-AA220AES
Features:
1. The flame and graphite furnace analysis device is fully automatic switching, convenient for time-saving, one click in place.
2. The flame system adopts high-reliability flow control and has automatic control such as automatic ignition.
3. Graphite furnace system built-in multiple temperature control protection system, using double air circuit breaker and other design methods, effectively preventing current overload or abnormal temperature rise.
4. Equipped with a reliable gas-liquid separation system, gas filter, and other accessories to ensure the working condition of the instrument when the ambient humidity is high and the gas source is limited.
5. Equipped with multiple safety interlocking devices and prompt information protection functions, the instrument has an automatic power outage, alarm prompts protection in case of abnormal situations involving safety.
6. The instrument features a modular design for easy customer replacement or repair.
7. The instrument supports functional extensions such as hydride method.
Technical Parameters:
Model
BK-AA220AES
Wavelength Range
170~900nm
Spectral Bandwidth
0.1, 0.2, 0.4, 1.6nm
Wavelength Accuracy
≤±0.1nm
Wavelength Repeatability
≤0.05nm
Detector
Photomultiplier tube detector
Baseline Stability
Drift ≤0.002Abs, noise ≤0.001Abs(Steady 30min)
Drift ≤0.002Abs, noise ≤0.001Abs(Dynamic 15min)
Resolution
Spectral bandwidth deviation ≤0.02nm
Manganese double line valley to peak energy ratio ≤25%
Characteristic Concentration/Content
Flame method for Cu: ≤0.025μg/mL/1%
Graphite furnace method for Cd: ≤0.5pg
Detection Limit
Flame method for Cu: ≤0.002μg/mL
Graphite furnace method for Cd: ≤0.4pg
Preciseness
Flame method for Cu: ≤0.3%
Graphite furnace method for Cd: ≤2.0%
Background Correction Ability
Deuterium lamp calibration 1.0Abs, background ≥90 times
Self-absorption method correction 2.0Abs, background ≥90 times
Diffraction Grating
Groove 1800lines/mm, blaze wavelength 250nm
Lamp Stand
8(Support simultaneous preheating of 1~4 lights)
Standard Accessory
Element lamp(Cu*1, Cd*1, Hg*1), software working station
Optional Accessory
Wide slit combustion head, adjustable nebulizer, hydride vapor generator, audit trailing software, oil-free air compressor, recirculating cooling water system, computer, printer, autosampler, oxygen-enriched high-temperature flame
Power Supply
AC220V, 50Hz
External Size(W*D*H)
Main unit: 1020*530*500mm
GF power supply: 350*530*430mm
Package Size(W*D*H)
Main unit: 1280*750*830mm
GF power supply: 610*670*810mm
Net Weight
Main unit: 85kg
GF power supply: 32kg
Gross Weight
Main unit: 160kg
GF power supply: 70kg
Flame System
Air-acetylene Burner
100mm all-titanium burner
Atomization Chamber System
Integrally molded from polyphenylene sulfide
Burner System
Burner head height and horizontal position automatic adjustment, with burner angle rotatable
Gas Flow Control System
Automatic ignition/fame-out
Safety System
Emergency shutdown protection switch, automatic gas cut-off/shutdown/alarm in case of abnormal status, abnormal air pressure, ignition failure, gas leakage, abnormal flow rate, etc.
Graphite Furnace System
Temp. Control Mode
Optical and constant voltage
Heating Mode
Slope and stepped temperature programming
Temp. Range
RT~3000℃
Heating Rate
≥3000℃/s
Precision Error
≤1%
Graphite Tube Type
Straight, platform, concave type
Water&Gas Control Monitoring System
Inner gas, external gas and make up gas are controlled separately. Circulating water and gas flows monitoring system is equipped
Safety System
Graphite furnace cut-off high current protection switch, automatic pause/cooling/alarm in case of abnormal furnace state/water and gas circuit control failure/graphite tube problem/temperature control failure, etc.
Software Working Station
Smart Optimization
One-key operation for instrument optimization, supporting multi-task analysis
Repeat Measurement
1~99 replicates with auto-calculation of mean/SD/RSD
Print/Export Reports
Word/Excel supported
Auto-Calibration
Curve fitting, re-slope&concentration calculation, incl. standard addition method
Model
BK-AA220AES
Wavelength Range
170~900nm
Spectral Bandwidth
0.1, 0.2, 0.4, 1.6nm
Wavelength Accuracy
≤±0.1nm
Wavelength Repeatability
≤0.05nm
Detector
Photomultiplier tube detector
Baseline Stability
Drift ≤0.002Abs, noise ≤0.001Abs(Steady 30min)
Drift ≤0.002Abs, noise ≤0.001Abs(Dynamic 15min)
Resolution
Spectral bandwidth deviation ≤0.02nm
Manganese double line valley to peak energy ratio ≤25%
Characteristic Concentration/Content
Flame method for Cu: ≤0.025μg/mL/1%
Graphite furnace method for Cd: ≤0.5pg
Detection Limit
Flame method for Cu: ≤0.002μg/mL
Graphite furnace method for Cd: ≤0.4pg
Preciseness
Flame method for Cu: ≤0.3%
Graphite furnace method for Cd: ≤2.0%
Background Correction Ability
Deuterium lamp calibration 1.0Abs, background ≥90 times
Self-absorption method correction 2.0Abs, background ≥90 times
Diffraction Grating
Groove 1800lines/mm, blaze wavelength 250nm
Lamp Stand
8(Support simultaneous preheating of 1~4 lights)
Standard Accessory
Element lamp(Cu*1, Cd*1, Hg*1), software working station
Optional Accessory
Wide slit combustion head, adjustable nebulizer, hydride vapor generator, audit trailing software, oil-free air compressor, recirculating cooling water system, computer, printer, autosampler, oxygen-enriched high-temperature flame
Power Supply
AC220V, 50Hz
External Size(W*D*H)
Main unit: 1020*530*500mm
GF power supply: 350*530*430mm
Package Size(W*D*H)
Main unit: 1280*750*830mm
GF power supply: 610*670*810mm
Net Weight
Main unit: 85kg
GF power supply: 32kg
Gross Weight
Main unit: 160kg
GF power supply: 70kg
Air-acetylene Burner
100mm all-titanium burner
Atomization Chamber System
Integrally molded from polyphenylene sulfide
Burner System
Burner head height and horizontal position automatic adjustment, with burner angle rotatable
Gas Flow Control System
Automatic ignition/fame-out
Safety System
Emergency shutdown protection switch, automatic gas cut-off/shutdown/alarm in case of abnormal status, abnormal air pressure, ignition failure, gas leakage, abnormal flow rate, etc.
Temp. Control Mode
Optical and constant voltage
Heating Mode
Slope and stepped temperature programming
Temp. Range
RT~3000℃
Heating Rate
≥3000℃/s
Precision Error
≤1%
Graphite Tube Type
Straight, platform, concave type
Water&Gas Control Monitoring System
Inner gas, external gas and make up gas are controlled separately. Circulating water and gas flows monitoring system is equipped
Safety System
Graphite furnace cut-off high current protection switch, automatic pause/cooling/alarm in case of abnormal furnace state/water and gas circuit control failure/graphite tube problem/temperature control failure, etc.
Smart Optimization
One-key operation for instrument optimization, supporting multi-task analysis
Repeat Measurement
1~99 replicates with auto-calculation of mean/SD/RSD
Print/Export Reports
Word/Excel supported
Auto-Calibration
Curve fitting, re-slope&concentration calculation, incl. standard addition method
Atomic Absorption Spectrophotometer BK-AA220AES — professional solution in the Spectrophotometers category
Atomic Absorption Spectrophotometer BK-AA220AES is a modern business-class equipment designed for daily operation in demanding conditions. The combination of reliability, accuracy and durability makes this product the optimal choice for companies seeking consistent process quality, predictable results and reduced operating costs. The purchase price is a reasonable investment in the development and scaling of the enterprise.
Why Atomic Absorption Spectrophotometer BK-AA220AES
- Reliability and durability: industrial-grade design and materials withstand intense loads.
- Accuracy and repeatability: stable performance that reduces the risk of defects and downtime.
- Process efficiency: optimizing staff time and increasing productivity at every stage.
- Compliance with standards: manufactured taking into account current international requirements for the business segment.
- Ease of integration: Atomic Absorption Spectrophotometer BK-AA220AES fits easily into existing process lines and IT infrastructure.
Areas of application Spectrophotometers
Spectrophotometers solutions are widely used in manufacturing, research laboratories, construction sites, energy and agricultural sectors, pharmaceutical and food industries. Implementing Atomic Absorption Spectrophotometer BK-AA220AES allows you to increase productivity, ensure accuracy of operations and optimize resource utilization across the entire enterprise.
Key benefits for business
Return on investment
Reduced service costs and downtime, predictive budget planning, fast ROI thanks to stable operation.
Scalability
Readiness to expand capacity and integrate with other solutions without re-engineering processes.
Safety and quality control
Compliance with standards, which simplifies audits and increases the trust of customers and partners.
Technical highlights
- Industrial reliability of components and assemblies for long-term trouble-free operation.
- Stable parameters that ensure repeatability of results and product quality.
- Energy efficiency and optimized life cycle cost of ownership.
- Compatibility with related equipment and standard data exchange protocols.
Service and support
Together with Atomic Absorption Spectrophotometer BK-AA220AES you receive professional advice on selection, commissioning and personnel training. We provide warranty and post-warranty service, prompt delivery of consumables and spare parts. Our team supports projects from the procurement stage to the stable operation of the complex so that your business receives the expected result every day.
To select a package for your needs or to receive a commercial offer, add Atomic Absorption Spectrophotometer BK-AA220AES to the cart or contact our manager. We will help integrate Spectrophotometers into existing processes without downtime and unnecessary costs.
No questions about this product, be the first and ask your question.