Gas Chromatograph BK-GC901
Features:
High-precision gas flow control system(EPC)
1. High-precision gas flow control, to ensure the accuracy of GC analysis, to ensure the efficiency of daily analysis, EPC control accuracy 0.01psi.
2. It realizes the self-protection of gas circuit failure, automatic ignition, re-ignition, automatic opening of the gas circuit, and one-key start.
3. A variety of control combination modes of operation, automatic pressure and flow adjustment, control and display, can operate in gas-saving mode.
Color widescreen, unique design of touch keys
1. 7-inch industrial color LCD screen design, more complete display information, more reasonable interface operation.
2. Have two sets of operating systems in Chinese and English to meet different user needs.
3. Adopt resistive touch screen, feel good, durable, double operation of screen and software to achieve seamless connection.
Leading structural design
1. Modular structure design, easy to upgrade, can be equipped with a variety of high-performance detectors such as FID, TCD, ECD, FPD and NPD, etc., to meet the analysis needs of complex samples.
2. Advanced sampler design, unique liner structure and special processing technology to ensure zero adsorption of samples.
3. Adapt to a variety of sample injection methods such as: headspace sampler, thermal desorption analyzer, liquid automatic sampler, easily competent for the analysis of various sample types.
4. Timed self-starting program can easily complete the laboratory online analysis of gas and liquid samples.
Humanized software operating system
1. Adopt advanced 10/100M self-adaptive Ethernet communication interface, built-in IP protocol stack, easily form a local area network, realize long-distance transmission, remote control, and remote diagnosis.
2. Equipped with IBrainChrom workstation, which can support multiple chromatographs(253 sets) to work at the same time, realize data processing and reverse control.
Data processing and countermeasure
1. Have complete audit trail, user rights management, electronic signature and other functions, so that data and documents meet GMP management requirements.
2. The built-in Modbus/TCP server of IBrainChrom workstation can easily connect the analysis results to DCS(distributed control system).
3. 3 independent connection threads that can be connected to local, laboratory supervisors and authorities, allowing them to monitor the operation of the instrument and analyze the data in real time.
Technical Parameters:
Model
BK-GC901
Oven
Temp. Range
RT+5~450℃
Temp. Accuracy
≤±0.01℃
Temp. Program
16-phase
Max. Temp. Heating Rate
40℃/min
Time Range
0~999.9min
Detector
Hydrogen Flame Ionization Detector(FID)
Detection Limit: ≤5×10-12g/s(100ng/μl n-hexadecane-isooctane solution)
Temperature 450℃
Compatible with packed and capillary columns
Baseline Drift: ≤2*10-13A/30min
Baseline Noise: 3*10-14A
Linear Range: ≥107
Thermal Conductivity Detector(TCD)
Sensitivity: >5000mv.ml/mg(50mg/ml toluene-benzene solution)
Temperature 400℃
Baseline Drift: ≤0.1mV/30min
Baseline Noise: 0.03mV
Linear Range: ≥105(±10%)
Electron Capture Detector(ECD)
Detection Limit: ≤1×10-14g/ml(Sample: n-hexadecane δ-666)
Linear Range: ≥104
Flame Photometric Detector(FPD)
Detection Limit: ≤5*10-12g/s(S of 10ng/μL methyl parathion-ethanol solution)
Detection Limit: ≤4*10-12g/s(P of 10ng/μL methyl parathion-ethanol solution)
Linear Range(S): ≥103
Linear Range(P): ≥104
Temperature 350℃
Nitrogen and Phosphorus Detector(NPD)
Detection Limit: ≤1*10-12g/s(Azobenzene)
Detection Limit: ≤1*10-12g/s(Marla sulfur phosphorous)
Linear Range: ≥103
Injection Method
Capillary column split/splitless sampling(with diaphragm purging function), packed column sampling, valve sampling, gas/liquid automatic sampling system, etc.
Inlet
1~4, up to 3 capillary column inlets
Injection Type
Packed column injection, capillary column injection.(Flow setting range: 0~1000ml/min)
Control Accuracy
Pressure: 0.01KPa; Flow: 0.01ml/min
Maximum Split Ratio
1:999
Pressure Sensor
Accuracy: <2% of full scale; Repeatability: <± 0.05KPa; Range: 0~0.6MPa
Flow Sensors
Accuracy: < 5% of full scale; Repeatability: 0.5KPa(full scale); Output offset(accuracy): ±5%
Sampling Valve
Can be equipped with multiple imported automatic control valves, which can run automatically in sequence
Power Supply
AC220V±10%, 50/60Hz
Standard Accessory
FID detector, Chromatography workstation software, Capillary sampler
Optional Accessory
Sample injection system, TCD, ECD, FPD and NPD detector, Chromatographic column
Package Size(W*D*H)
750*710*720mm
Gross Weight
70kg
Data processing and countermeasure
Technical Parameters:
Model
BK-GC901
Oven
Temp. Range
RT+5~450℃
Temp. Accuracy
≤±0.01℃
Temp. Program
16-phase
Max. Temp. Heating Rate
40℃/min
Time Range
0~999.9min
Detector
Hydrogen Flame Ionization Detector(FID)
Detection Limit: ≤5×10-12g/s(100ng/μl n-hexadecane-isooctane solution)
Temperature 450℃
Compatible with packed and capillary columns
Baseline Drift: ≤2*10-13A/30min
Baseline Noise: 3*10-14A
Linear Range: ≥107
Thermal Conductivity Detector(TCD)
Sensitivity: >5000mv.ml/mg(50mg/ml toluene-benzene solution)
Temperature 400℃
Baseline Drift: ≤0.1mV/30min
Baseline Noise: 0.03mV
Linear Range: ≥105(±10%)
Electron Capture Detector(ECD)
Detection Limit: ≤1×10-14g/ml(Sample: n-hexadecane δ-666)
Linear Range: ≥104
Flame Photometric Detector(FPD)
Detection Limit: ≤5*10-12g/s(S of 10ng/μL methyl parathion-ethanol solution)
Detection Limit: ≤4*10-12g/s(P of 10ng/μL methyl parathion-ethanol solution)
Linear Range(S): ≥103
Linear Range(P): ≥104
Temperature 350℃
Nitrogen and Phosphorus Detector(NPD)
Detection Limit: ≤1*10-12g/s(Azobenzene)
Detection Limit: ≤1*10-12g/s(Marla sulfur phosphorous)
Linear Range: ≥103
Injection Method
Capillary column split/splitless sampling(with diaphragm purging function), packed column sampling, valve sampling, gas/liquid automatic sampling system, etc.
Inlet
1~4, up to 3 capillary column inlets
Injection Type
Packed column injection, capillary column injection.(Flow setting range: 0~1000ml/min)
Control Accuracy
Pressure: 0.01KPa; Flow: 0.01ml/min
Maximum Split Ratio
1:999
Pressure Sensor
Accuracy: <2% of full scale; Repeatability: <± 0.05KPa; Range: 0~0.6MPa
Flow Sensors
Accuracy: < 5% of full scale; Repeatability: 0.5KPa(full scale); Output offset(accuracy): ±5%
Sampling Valve
Can be equipped with multiple imported automatic control valves, which can run automatically in sequence
Power Supply
AC220V±10%, 50/60Hz
Standard Accessory
FID detector, Chromatography workstation software, Capillary sampler
Optional Accessory
Sample injection system, TCD, ECD, FPD and NPD detector, Chromatographic column
Package Size(W*D*H)
750*710*720mm
Gross Weight
70kg
Gas Chromatograph BK-GC901 — професійне рішення у категорії Gas Chromatograph
Gas Chromatograph BK-GC901 — сучасне обладнання бізнес-класу, створене для щоденної експлуатації у вимогливих умовах. Поєднання надійності, точності та довговічності робить цей продукт оптимальним вибором для компаній, які прагнуть стабільної якості процесів, прогнозованих результатів і скорочення операційних витрат. Вартість придбання — є доцільною інвестицією у розвиток та масштабування підприємства.
Чому саме Gas Chromatograph BK-GC901
- Надійність і ресурс: конструкція та матеріали промислового класу витримують інтенсивні навантаження.
- Точність і повторюваність: стабільні показники, що зменшують ризики браку і простоїв.
- Ефективність процесів: оптимізація часу персоналу та підвищення продуктивності на кожному етапі.
- Відповідність стандартам: виготовлено з урахуванням актуальних міжнародних вимог для бізнес-сегмента.
- Простота інтеграції: Gas Chromatograph BK-GC901 легко вписується у наявні технологічні лінії та ІТ-інфраструктуру.
Сфери застосування Gas Chromatograph
Рішення формату Gas Chromatograph широко використовуються на виробництвах, у дослідницьких лабораторіях, на об’єктах будівництва, в енергетичному та агросекторах, фармацевтичній і харчовій промисловості. Впровадження Gas Chromatograph BK-GC901 дає змогу підвищити продуктивність, забезпечити точність операцій і оптимізувати використання ресурсів у масштабах усього підприємства.
Ключові переваги для бізнесу
Окупність інвестицій
Зменшення витрат на сервіс і простої, прогнозоване планування бюджету, швидкий ROI завдяки стабільній роботі.
Масштабованість
Готовність до розширення потужностей та інтеграції з іншими рішеннями без переробки процесів.
Безпека та контроль якості
Відповідність стандартам, що спрощує аудит і підвищує довіру клієнтів та партнерів.
Технічні акценти
- Промислова надійність компонентів і вузлів для тривалої безвідмовної роботи.
- Стабільні параметри, що забезпечують повторюваність результатів і якість продукції.
- Енергоефективність та оптимізована вартість володіння протягом життєвого циклу.
- Сумісність із суміжним обладнанням та стандартними протоколами обміну даними.
Сервіс і підтримка
Разом із Gas Chromatograph BK-GC901 ви отримуєте професійну консультацію щодо добору, введення в експлуатацію та навчання персоналу. Надаємо гарантійне й післягарантійне обслуговування, оперативну поставку витратних матеріалів та запчастин. Наша команда супроводжує проєкти від етапу закупівлі до стабільної роботи комплексу, щоб ваш бізнес отримував передбачуваний результат щодня.
Щоб підібрати комплектацію під ваші задачі або отримати комерційну пропозицію, додайте Gas Chromatograph BK-GC901 до кошика або зверніться до нашого менеджера. Ми допоможемо інтегрувати Gas Chromatograph у діючі процеси без простоїв та зайвих витрат.
Немає питань про даний товар, станьте першим і задайте своє питання.